1. communicationerror,10061winsock?
The system error 10061 in Winsock generally indicates that a connection attempt to a socket was refused. There can be multiple reasons behind this error, such as:1. The target server is not listening on the specified port.2. The target server is busy and unable to handle the connection request.3. There is a network connectivity issue between the client and server.4. A firewall or anti-virus software is blocking the connection.To resolve this error, you can try the following troubleshooting steps:1. Verify that the target server is running and listening on the expected port.2. Check if any firewall or anti-virus software is enabled and configure it to allow the required communication.3. Confirm that the network connection between the client and server is stable.4. Temporarily disable any firewall or anti-virus software to test if they are blocking the connection.5. Ensure that the client is using the correct IP address and port to connect to the server.If none of the above steps resolve the issue, you may need to consult with your network administrator or contact the server/application support for further assistance.
2. 法拉克数控车床出现9110报警是什么意思?
放大器与模块间的通讯错误
解决方法:1 更换通讯电缆
2 更换 SPM 或SPM 控制电路板
报警原因:主轴放大器与电源放大器间通讯异常
多数是前一次操作结束,某工位尚未彻底退回原点复位而报警,或者是操作中断电源,因程序尚未结束报警……建议试手动态下,人工操作返回起始点。若人工也无法返回,这说明此工位曾在运行中受到严重碰撞而失问步,那必须重校机电同步,否则根本不能再进行自动运行态操作了
3. 连接mysql错误2013?
展开全部
Mysql mysql lost connection to server during query 问题解决方法
缘由: 在查询Mysql中的数据库,或者修改比较大的表的时候就会出现这种情况;
google之:
方案1.在mysql配置文件[myslqd]下面添加一行设置skip-name-resolve.需要重启mysql服务.
方案2.在hosts文件内添加: ip与主机名的映射关系,如: 127.0.0.1 localhost. 这种方式不用重启mysql服务.
---------------------------
三个层面上解决这个问题:
1. 代码层面,你需要在自己的PHP数据库连接处增加大致如下代码。
if( in_array(mysql_errno(), array(2006, 2013))){
mysql_close();
mysql_connect(...);
mysql_query(...);
}
也就是说遇到2006,2013错误就重新连接一下MySQL。
2. MySQL层面,需要配置一些参数 my.cnf (但是这里是linux下,我的windows配置怎么办?)
wait_timeout = x 超时时间 如600秒
max_allowed_packet = y 最大允许数据量
适当增加x,y的值。
3. 一般出现这种情况不是所有例句而是单个表,请你先修复表一般都能解决这类问题。
----------------------
MySQL Error 2013: Lost connection to MySQL server during query
错误代码: 1153 - Got a packet bigger than 'max_allowed_packet' bytes
解决方法:
修改mysql.ini(网上都说是这个文件,找了N久终于知道在哪里了,我的目录是在 D:\MySQL_Data\MySQL Server 5.5 在MySQL_Data文件夹下)文件添加如下代码即可
max_allowed_packet=500M
如果不可以的话就修改F:\program\mysql5.0\my-huge.ini
里的max_allowed_packet=16M 把16改为500 /////////////我用这个方法解决的 2014-6-4 19:58 //////////
个人理解就是把mysql配置所提供的最大允许内存改大了毕竟16M可能不够
我是根据此方法做的,试试
----------------------
4. 可以直接在mysql中设置:
#show variables like '%timeout%';
#show variables like 'max_allowed_packet'
set global wait_timeout=60000;
#set global max_allowed_packet = 2*1024*1024
4. 地磅仪表出现ECC是什么意思?
地磅仪表出现ECC意味着仪表出现了错误控制码,通常是由于数据传输过程中发生了错误所致。这种错误可能会导致数据的丢失或损坏,从而导致地磅读数不准确。为了解决这个问题,需要检查仪表的电路连接是否稳定,确保数据传输的稳定性,同时检查仪表是否需要更新或更换。此外,在使用地磅时,也应该注意仪表的维护和保养,以确保其正常工作。
5. 英泰变频器故障代码?
1、E-Stop (急停):急停按钮已被触发,变频器停止工作以确保安全。
2、Overvoltage (过压):输入电压过高,导致变频器保护措施生效。
3、Undervoltage (欠压):输入电压过低,导致变频器保护措施生效。
4、Overcurrent (过流):输出电流过高,变频器保护触发。
5、Overload (过载):输出负载过重,变频器无法提供足够的电流。
6、Short Circuit (短路):输出短路,导致变频器保护机制生效。
7、Overtemperature (过温):变频器温度过高,触发保护机制。
8、Ground Fault (接地故障):输出或输入电路存在接地故障。
9、Communication Error (通信错误):变频器与外部设备(如PLC)之间的通信出现问题。
10、Motor Phase Loss (电机缺相):电机缺少一个或多个相位。
11、Motor Overload (电机过载):电机承载过重,变频器无法提供足够的功率。
12、Encoder Fault (编码器故障):与电机编码器相关的问题,如信号丢失或损坏。
13、DC Bus Fault (直流母线故障):直流母线电压异常,可能是电容器故障或其他电路问题。
14、Inverter Fault (逆变器故障):逆变器电路出现问题,导致变频器无法正常工作。
15、Parameter Error (参数错误):变频器参数设置错误或超出范围。
6. 怎么样才能把爱普生r330的电机热保护关掉?
打开清零软件,点击Select 选择(拉开选项栏选中你的打印机所在端口),再点击 Particular adjustment mode (单项调试模式)进入主菜单后,选择执行过程中,如果出现Communication error 这个提示的话,需再次点击Perform 完成后,退出调试程序,做好保持打印机断电状态约一小时。
7. 遇到connection?
一旦遇到“Connection reset”错误,应该首先检查网络连接,以查看是否有问题。如果计算机和服务器都存在问题,应尝试用另一台计算机或者手机重新连接。如果服务器出现问题,则应尝试重新启动服务器或者重新安装服务器上的程序。